Logo B

Pipette.com Calibration Services

Our 17025 ISO accredited and FDA registered facility has been servicing nationwide for 21+ years. We work with labs of all sizes and provide service for all brands and models.

Pipette.com Calibration Facility

Pipette.com Calibration Facility

Pipette.com is an ISO 17025 Accredited Calibration Facility that calibrates and repairs all pipette brands and models.

Order In-Lab Pipette Calibration

Calibration Promo: Free Shipping!

Free shipping when you send in 15 or more pipettes for calibration

View Deal
Get Calibration Quote
Services We Provide

Verification Calibration Calibration PLUS
Is This Right For My Lab?
  1. Are there new pipettes that require a calibration due date?
  2. Do you need to demonstrate your pipettes are within manufacturer specifications in between calibration cycles?
  1. Do you want to extend the longevity of your pipettes?
  2. Are your pipettes routinely utilized in the laboratory?
  1. Do you verify your pipettes in the lab in between calibration cycles?
  2. Is your laboratory a GLP, CLIA, manufacutring, or audited laboratory?
  3. Are you obtaining odd results that could be attributed to incorrect volumes?
Calibration Overview Pipettes are confirmed to be within or out of manufacturer’s specifications in an environmentally controlled facility. Pipettes undergo preventive maintenance (PM) and calibrated to manufacturer specifications. Pipettes undergo verification first, and then preventative maintenance.
Benefits Pipettes are confirmed to be within or out of manufacturer’s specifications. This is also a cost-effective way to obtain a calibration due date on new pipettes facility. Preventative maintenance (PM) proactively replacing parts that are known to fail before they affect the performance of the pipette. Many pipettes that are out of tolerance fail because PM parts have worn out. You can demonstrate your pipettes are within calibration range before they undergo preventative maintenance and calibration. Alternatively, if your pipettes are out of tolerance, you can adjust future calibration intervals to be closer together.
Calibration Services Glossary

Pipette Verification

Pipettes undergo a Leakage Test, Functional Test, and Calibration Check are performed with 4x2 weighings.

Preventative Maintenance

Each pipette is completely dissembled, cleaned inside & out, pistons are polished & re-greased, and seals &/or o-rings are replaced as needed (as specified by the manufacturer, make, & model) then reassembled. Parts that can wear-out are proactively replaced

Online Data Reports Retrieving & Pipette Management Tool

Instantly access a pipette's history, calibration reports and calibration due date on line with our free pipette management tool

Pipette Calibration

Every pipette undergoes 4x2 weighings (2 at low volume & 2 at high volume as specified by manufacturer requirements) in an environmentally controlled calibration facility. Extended calibration points & weighings, and individual channel calibration for multichannel pipettes are available upon request

3rd Point Reading (per channel)

Median point (4 weighings) can be added to any calibration order

Extended 10×2 Readings (per channel)

Extended Measurements takes 10 measurements at 2 data points (10×2) to provide more statistical data compared to the 4×2 weighings

Multi-Channel Readings (per channel)

Each channel of the multichannel pipette is individually adjusted, weighed, and calibrated. Recommended for precise, quantitative work

DNA/RNA Decontamination

Removes existing DNA and RNA contamination, such as over aspirated oligonucleotides

Complimentary Paper Report

Each Report provides detailed pipette information, mean, standard deviation, and variance of weighings, pipette performance status listed as Pass/ fail, lab conditions during the calibration process, list of parts used in repair, computer-generated barcode linking to online report

Calibration Label

Every serviced pipette receives a calibration or verification sticker with a scannable barcode and comprehensive information including the calibration date, next calibration due date, and serial number. Optional information such as user, equipment number and location can also be included on the label

Automated Email Reminders for Your Next Calibration Service Date

You can choose to be notified via email 4 weeks to 6 weeks before the pipette calibration due date

Printed Copy of GMP/ GLP Calibration Report

Includes all of the features of the complimentary report plus the individual weighings in addition to the mean, a dedicated certificate for each pipette, detailed information on the equipment utilized by Pipette.com, and detailed technician information

24 Hour Service

1 Business day pipette calibration turn-around is available for $10 per pipette

Frequently Asked Questions

What is pipette calibration?

It is a process of examining and/or adjusting the pipettes to the true value by comparison to the standard which is set by the manufacturer of that said pipette. The standard in this case is the pipetting range set by the pipette manufacturer to be accurate and precise at low volume and high volume of the pipette. At Pipette.com, we perform metrology based pipette calibration; Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes

Why is metrology based pipette calibration important?

Metrology is defined as a science of measurement. Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes. If this standard is not followed there cannot be a statistical guarantee that your results are accurate to true standards. Science is based on reproducible results. When reproducible results cannot be achieved all work is voided. Thus, scientists must strive that all of their work is reproducible. In order to achieve reproducibility scientists must have accurate and precise equipment. Pipettes are the cornerstone of all research, thus they must always be precise and accurate. In order to achieve this scientists must choose pipette service providers that follow strict metrology guidelines. Providers whose equipment is also calibrated and follows strict NIST rules can provide accurate and precise results giving you informative data on the status of your work and your pipette. Without metrology based calibration one cannot statistically say if the pipette is truly within range, it is simply an assumption using an uncertified piece of equipment

Are your technicians trained by manufacturers?

Are your technicians trained by manufacturers?

What types of pipettes do you repair & calibrate?

Single channel manual pipettes and electronic pipettes Multichannel manual pipettes and electronic pipettes 4-channel pipettes 6-channel pipettes 8-channel pipettes 12-channel pipettes 16-channel pipettes 48-channel pipettes 64-channel pipettes 96-channel pipettes Positive displacement pipettes Repeaters Bottletop dispensers Burettes Motorized controllers

Can you calibrate Rainin pipettes?

Yes, we can calibrate Rainin pipettes and repair Rainin pipettes

What brands of pipettes do you repair & calibrate?

Accupet Pipettes Biohit Pipettes BrandTech Pipettes CAPP Pipettes Cole-Palmer Pipettes Drummond Pipettes Eppendorf Pipettes Labnet Pipettes Matrix Pipettes Nichiryo Pipettes Oxford Lab Products Rainin Pipettes Sartorius Pipettes Socorex Pipettes Falcon Pipettes Gilson Pipettes Hamilton Pipettes Heathros Pipettes Hirschmann Pipettes Integra Bioscienc Pipettes Jencons Pipette

Do you repair Pipet-Aids?

Yes, we can repair Pipet-Aids and motorized controllers

What is preventative maintenance (PM)?

Preventative Maintenance (PM) is a step in the calibration process that greatly enhances the longevity of your instrument. PM includes full disassembly, interior & exterior cleaning, piston polishing & re-greasing, and new seals/o-rings are replaced as needed. An in-depth PM process helps keep your pipettes operating at peak performance in between your regularly scheduled calibration service dates

Do you perform calibration on site?

Yes, we do offer onsite services for calibration. For quotation, pricing, and availability of our onsite calibration services, please feel free to reach out to us at service@pipette.com. We'd be happy to assist you with all the information you need.

Accuracy & Precision is important when I use my multichannel pipette, what calibration plan would you recommend?

We recommend adding individual channel calibration for your multichannel pipette if you need each channel to be precise and accurate (such as when preforming RT-PCR, ELISA, ECL and Bioassays). This means each channel is individually adjusted, weighed, and calibrated. To add this to any pipette calibration service, check the box for “Multi-Channel Readings (per channel) on the “Pipette Service Order Form”

How much does it cost to fix my broken pipette?

We provide free repair estimates once the broken pipette is in our calibration facility. We only charge you for pipette calibration and replacement parts

Additional Calibration Information

Have you used our calibration or repair services? Tell us how we did by taking a short survey!

Take the Survey

Gilson

Gilson Pipettes Have Been Providing Accuracy and Precision for Over 40 Years Gilson Pipetman™ and Microman™ pipettes are one of the most commonly used pipettes in a lab. Gilson created the Pipetman in the 1970s and today they continue to develop innovative Gilson pipettes like the new Pipetman L™. Renowned for their high quality, durable, and accurate pipettes, Gilson continues to be an industry leader in liquid handling. Built with newly engineered springs, the Gilson Pipettes have low force plungers to reduce strain on operators. The tip-holders and tip-ejectors are fully autoclavable to prevent any cross-contamination that might occur. The latest pipette from Gilson, the Pipetman L, is extremely lightweight, weighing just 90 grams. It is fully adjustable and is available in 8 single channel models which cover a volume range of 0.32 uL to 10 mL. Designed for ergonomics with the risk of repetitive strain injury on mind, the Pipetman L is Gilson’s answer to every scientist’s question about how to remain injury free while continually pipetting. Biotix Cobra Pipettes by Gilson are an aesthetic line of pipettes that are designed for comfort and accuracy. Dubbed one of the most comfortable pipettes on the market and designed with extremely low force requirements for pipetting, these pipettes can produce accurate measurements from 0.2 uL to 1000 uL. Fully autoclavable and designed with stainless-stell pistons, the Biotix Cobra pipettes are the perfect line of pipettes for any laboratory. The traditional Pipetman is also fully adjustable, air displacement, and comes in 8 single channel models covering the same volume range as the Pipetman L. It is made of stainless steel and PVDF, a plastic that has a high resistance to chemicals. Gilson pipettes are known for their durability and precision.