Eppendorf Adapter 5x1.1-1.4mL F/4x85 Pk/2 (5702)
Adapter 5x1.1-1.4mL F/4x85 Pk/2 (5702)
Product Description:
Eppendorf Centrifuge 5702 is the ideal centrifuge for low to mid throughput labs.
Manuals
- Operating Manual for the Centrifuge 5702 family
- Instructions for use of the 85 mL round bucket
- Leaflet Centrifuge MiniSpin family 5702
- Instructions for use of Rotor A 8 17
Related Articles
Specifications
Centrifuge 5702 |
Centrifuge 5702 R |
Centrifuge 5702 RH |
|
Max g-force |
3,000 rcf |
3,000 rcf |
3,000 rcf |
Speed range |
100-4,400 rpm |
100-4,400 rpm |
100-4,400 rpm |
Capacity |
4 x 100 mL tubes |
4 x 100 mL tubes |
4 x 100 mL tubes |
Number of rotors |
6 |
6 |
6 |
Capacity for 1.5 mL |
24 |
24 |
24 |
Capacity for 50 mL conical tubes |
4 |
4 |
4 |
Refrigeration |
No |
Yes |
Yes, with active heating |
Temperature control range |
N/A |
-9°C to 40°C |
-9°C to 42°C |
Power supply |
120 V, 50/60 Hz |
120 V, 50/60 Hz |
120 V, 50/60 Hz |
Power consumption |
max. 200 W |
max. 380 W |
max. 380 W |
Acceleration time to max speed |
<25 s (in A-4-38) |
<25 s (in A-4-38) |
<25 s (in A-4-38) |
Braking time to max speed |
<25 s (in A-4-38) |
<25 s (in A-4-38) |
<25 s (in A-4-38) |
Acceleration/Brake speed settings |
2 |
2 |
2 |
Timer |
0 to 99 min, with cont. mode |
0 to 99 min, with cont. mode |
0 to 99 min, with cont. mode |
Noise level |
<51 dB(A) |
<45 dB(A) |
<45 dB(A) |
Dimensions (W x D x H) |
12.5 x 15.6 x 9.5 in / 32 x 40 x 24 cm /p> |
15 x 22.8 x 10.2 in / 38 x 58 x 26 cm /p> |
15 x 22.8 x 10.2 in / 38 x 58 x 26 cm /p> |
Height with lid open |
20.7 in / 52.5 cm /p> |
23.4 / 59.4 cm /p> |
23.4 / 59.4 cm /p> |
Weight |
44 lb / 20kg / > |
78 lb / 36kg / > |
78 lb / 36kg / > |
Benefits of the Eppendorf Centrifuge 5702
- Speed up your work. FastTemp function for fast & accurate pre-cooling.
- Get the results you want. Various fixed angle & switch-bucket rotor & an extensive range of adapters, nearly all types of tubes can be used.
- Better design & construction compared to competitors. Stainless steel rotor chamber that is rust proof & removable making it easy to clean.
- Absolute control of your results. Soft break option for slow acceleration & braking. Optimal for cell separation by gradient centrifugation.
- Easy maintenance. Built-in condensation drain to eliminate water accumulation & prevent corrosion in the Refrigerated & Heater Model 5702 RH.
- Excellent warranty. Eppendorf Centrifuge Model 5702 comes with a 2-year warranty.
- Perfect temperature control. Extended temperature control from –9 °C to 42°C. Active heating & cooling guarantees high temperature accuracy (± 1°C at 4°C & 37°C) during the entire centrifugation cycle for the Refrigerated & Heated Model 5702 RH.
- Use Refrigerated Model 5702 R for heat sensitive samples. Heated & Refrigerated Model 5702 RH allows centrifugation under biological conditions to improve cell viability for more accurate results in downstream application.
Eppendorf Centrifuge 5702
- Maximum speed of 3,000 x g (4,400 rpm), increments of 100 rpm
- Stainless steel rotor chamber is rust-free
- ECO shut-off engages after 8 hours of non-use
- Automatic imbalance detector
- Quiet operation
- Very compact design
- Low access height
- Automatic motorized locking of the lid
- Optimized airflow directed backwards
- Switch between rpm & rcf
- Separate Short Spin button
- Timer can be set for up to 99 minutes
- Continuous mode can be selected
- Parameter locking
- Glass window for quick calibration check
- Six rotor options
- SOFT brake function for delicate samples
- “At Set” function starts timer when set speed is reached for reproducible results
- Optimized braking ramp for isolation of mononuclear blood cells using Ficoll density gradient centrifugation
Model 5702 R (refrigerated) – Additional Features
- Adjustable from -9° to +40°C
- Standby refrigeration
- "At temp" function – quickly reach set temperature
- ECO shut-off engages after 8 hours of non-use to reduce energy consumption & extend compressor life
- Built-in condensation drain to eliminate water accumulation & prevent corrosion
- Use for safe holding at 4°C
Model 5702 RH (refrigerated & heated)
- Adjustable from -9° to +43°C
- Immediately ready for use via standby heating/refrigeration
- Temperature holds steady at 4°±1°C & 37°C±1°C
- Active heating
- Precise temperature control, software controlled depending on rotor
- Two programming keys to store routine procedures
- Ideal for conjugation of sperm in IVF labs & spin-down of temperative-sensitive active humam cells
- Temperature settings from -9°C to 40°C (5702 R) / 42°C (5702 RH)
- Centrifuge 5702 RH allows centrifugation under biological conditions to improve viability for more accurate results in downstream (e.g. cell cultivation)
Included 4 x 100mL Swing-Bucket Rotors
- Aluminum, round buckets with aerosol-tight caps available
- Maximum rotational speed: 4400rpm (maximum rcf: 3000xG)
- Square buckets available for use with glass, round-bottom tubes
Included Adapters (selected models)
- 4 x 13mm O.D. adapters & 4 x 16mm O.D. adapters
- 4 x15 & 4 x 50mL Conical adapters
Specifications & Ordering Information: Max. power requirements, Model 5702: 200w; Models 5702 R, RH: 380w. Power supply, all models: 230V 50Hz. Dimensions (L x W x H), Model 5702: 15.7 x 12.6 x 9.4 in. (40 x 32 x 2 cm ; Models 5702 R, RH: 22.8 x 15.0 x 10.2 in. (58 x 38 x 2 cm . Weight, Model 5702: 44.0 lb. (20kg); Models 5702 R, RH: 79.4 lb. (36kg). Compliance: Conform to CE, UL, cUL, IVD requirements